HF-S 3601 (circ.) Recipe "S"
Description: black cable compound that is UV resistant, halogen-free, and has low smoke emission.
Application: recommended for use as insulation for power, telecommunications, and special cables. The allowable operating temperature is not lower than -60°C, and installation must be done at temperatures not lower than -35°C.
TU 20.16.59-007-63982493-2020
Technical specifications
Indicator Name | Test Results | Technical Requirements | Testing Method |
Tensile strength before aging, MPa | 12,7 | > 10,5 | GOST IEC 60811-501 |
Elongation at break before aging, % | 193 | > 150 | GOST IEC 60811-501 |
Melt flow rate, (2.16 kg/160°C) | 9,5 | 6÷17 | GOST 11645 (GOST IEC 60811-511) |
Oxygen index, OI | 37 | ≥ 36 | GOST 21793 |
Density, g/cm³ | 1,48 | 1,46 ÷1,54 | GOST IEC 60811-606 |
Moisture content, % | 0,11 | ≤ 0,2 | ASTM D 6980 |
Shore D hardness | 52 | > 48 | GOST 24621 (ISO 868:2003) |
Volume resistivity at 20 °C | 4*1014 | >1013 | GOST 6433.2 |
Temperature resistance:
|
|
|
GOST 20.57.406 (метод 211-1) |
Aging in artificial atmosphere
|
|
|
GOST IEC 60811-401-2015 |
Gas corrosivity indicators
|
|
|
GOST IEC 60754-1 IEC 60754-2 IEC 60754-2 |
Maximum optical smoke density Dmax,
|
|
|
GOST 24632 |
Recommended temperature profile, °C (±10°C):
Z1 | Z2 | Z3 | Z4 | Z5 | Clamp | Adapter | Head |
125 | 130 | 135 | 140 | 145 | 145 | 150 | 150 |
Maximum melt temperature: not more than 190 °C (provided that the moisture content in the composition does not exceed 0.2%. If exceeded, drying is mandatory).
The product is supplied in granule form. It can be packed in corrugated cardboard octabins, soft containers like "big bags". Undamaged packaging ensures the preservation of the material for 12 months when stored at a temperature not exceeding 30 °C and a relative air humidity of 40 – 70%. Before processing the composition, it is recommended to dry at 60°C for 20-50 minutes. Regular periodic cleaning of the material supply system is recommended.